DSpace Repository

Simulation and Experimental Validation of Unfilling Defect Found In Connecting Rod in Close Die Forging

Show simple item record

dc.contributor.author Soyaliya, R.K.
dc.contributor.author Parmar, K.V.
dc.contributor.author Kanani, J.B.
dc.date.accessioned 2020-09-02T10:55:23Z
dc.date.available 2020-09-02T10:55:23Z
dc.date.issued 2016-04-01
dc.identifier.citation Soyaliya, R.K. & Parmar, K.V. & Kanani, J.B.(2016). SIMULATION AND EXPERIMENTAL VALIDATION OF UNFILLING DEFECT FOUND IN CONNECTING ROD IN CLOSE DIE FORGING. International Journal Of Advance Research And Innovative Ideas In Education, 2(3), 3958-3960.http://ijariie.com/FormDetails.aspx?MenuScriptId=1545 en_US
dc.identifier.issn 2395-4396
dc.identifier.uri http://ijariie.com/FormDetails.aspx?MenuScriptId=1545
dc.identifier.uri http://10.9.150.37:8080/dspace//handle/atmiyauni/598
dc.description.abstract Process of manufacturing of connecting rod in close die forging is studied. Defects found in connecting rod are unfilling, cracks, scale pits and lap. Unfilling defect contributed more toward rejection. To reduce unfilling defect, simulation is to be carried out in FEM based software DEFORM 3D, to visualize the mate rial flow in die cavity. Temperature range is to be found during simulation in DEFORM 3D, where there is complete filling of material in die i.e. removal of unfilling defect. Experiments are to be carried out at temperature range to validate DEFORM 3D result . en_US
dc.language.iso en_US en_US
dc.publisher International Journal of Advance Research and Innovative Ideas in Education en_US
dc.subject Unfilling defect, Deform 3D,simulation ,temperature range. en_US
dc.title Simulation and Experimental Validation of Unfilling Defect Found In Connecting Rod in Close Die Forging en_US