dc.contributor.author |
Desai, Rajesh |
|
dc.contributor.author |
Dhalani, Jayesh |
|
dc.contributor.author |
Koradiya, Suresh |
|
dc.contributor.author |
Nariya, Pankaj |
|
dc.date.accessioned |
2023-05-08T04:28:06Z |
|
dc.date.available |
2023-05-08T04:28:06Z |
|
dc.date.issued |
2022 |
|
dc.identifier.citation |
Desai, R., Dhalani, J., Koradia, S., & Nariya, P. (2022). ANALYTICAL STUDY AND IMPURITY PROFILING OF FIXED DOSES COMBINATION OF AMLODIPINE, HYDROCHLOROTHIAZIDE AND OLMESARTAN BY RP-HPLC AND UPLC. International Journal of Pharmaceutical Sciences and Drug Research, 14(1), 19-28. https://doi.org/10.25004/IJPSDR.2022.140103 |
en_US |
dc.identifier.issn |
0975-248X |
|
dc.identifier.uri |
http://10.9.150.37:8080/dspace//handle/atmiyauni/869 |
|
dc.description |
The authors are thankful to the Department of Chemistry,
School of Science, RK University, Rajkot for providing
resources to prepare the manuscript |
en_US |
dc.description.abstract |
A specific and sensitive reverse phase high pressure liquide chromatography (RP-HPLC) and ultra-performance liquide chromatography (UPLC) method for the determination of related substances for
fixed-dose combination formulation of Amlodipine Besylate, Hydrochlorothiazide and Olmesartan
Medoxomil was developed and validated. By using the gradient RP-HPLC method, a total of 25 known and
unknown impurities related to Amlodipine Besylate, Hydrochlorothiazide and Olmesartan Medoxomil in
combination formulation were separated and quantified in the linearity range of (0.2 to 3.0 µg/mL) for
Amlodipine Besylate, (0.5 to 7.5 µg/mL) for Hydrochlorothiazide and (0.8 to 12.0 µg/mL) for Olmesartan
Medoxomil with good squared correlation (>0.99). The recovery study was established from LOQ (0.05%)
to 150% of the specification limit. A precision study was performed by spiking each known impurities at the
specification level. In this study, two separate analytical methods RP-HPLC and UPLC have been developed,
validated, and compare for the simultaneous quantification of Amlodipine Besylate, Hydrochlorothiazide,
and Olmesartan Medoxomil tablets with their impurities. In these methods total of 28 peaks were separated
in 70 minutes run time by HPLC method while in 45 minutes by UPLC method. Both the methods are
developed with high selectivity, sensitivity, and robustness to separate 28 peaks in a single method. The
proposed methods have a high degree of sensitivity and will provide fast and cost-effective quantitative
control of Pharmaceutical formulations. |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
International Journal of Pharmaceutical Sciences and Drug Research |
en_US |
dc.subject |
Amlodipine Besylate |
en_US |
dc.subject |
HPLC |
en_US |
dc.subject |
Hydrochlorothiazide HCl |
en_US |
dc.subject |
Olmesartan Medoxomil |
en_US |
dc.subject |
UPLC |
en_US |
dc.title |
Analytical study and impurity profiling of fixed doses combination of amlodipine, hydrochlorothiazide and olmesartan by RP-HPLC and UPLC |
en_US |
dc.type |
Article |
en_US |