DSpace Repository

RP-HPLC method development, validation and pharmacokinetic applicability in preclinical evaluation of rhein treated with novel diacerein eutectics

Show simple item record

dc.contributor.author Patel, Rajeshri D.
dc.contributor.author Raval, Mihir K.
dc.contributor.author Pethani, Trupesh M.
dc.contributor.author Waghela, Bhargav N.
dc.contributor.author Shukla, Riddhi H.
dc.contributor.author Buch, Prakruti R.
dc.contributor.author Vadalia, Jigna M.
dc.contributor.author Sharma, Tejas P.
dc.contributor.author Airao, Vishal A.
dc.date.accessioned 2023-05-15T04:42:07Z
dc.date.available 2023-05-15T04:42:07Z
dc.date.issued 2019-07
dc.identifier.citation : Patel, R. D., Raval, M. K., Pethani, T. M., Waghela, B. N., Shukla, R. H., Buch, P. R., Vadalia, J. M., Sharma, T. P., & Airao, V. A. (2022). RP-HPLC method development, validation and pharmacokinetic applicability in preclinical evaluation of rhein treated with novel diacerein eutectics. Biomedical Chromatography, e5465. https://doi.org/ 10.1002/bmc.5465 en_US
dc.identifier.issn 0269-3879
dc.identifier.uri http://10.9.150.37:8080/dspace//handle/atmiyauni/931
dc.description This work was funded in part by the Department of Science and Technology (DST), India: Project for DST-INSPIRE Fellowship programme DST/INSPIRE Fellowship/2013/1079. en_US
dc.description.abstract The current study represents a bioanalytical method for the estimation of rhein (Rh, an active metabolite of diacerein, DIA) in rats treated with novel DIA eutectics to investigate the pharmacokinetics of DIA. A simple protein precipitation technique was used to extract Rh and the internal standard (IS), p-aminobenzoic acid, injected into a Phenomenex Gemini C18 column. The separation was achieved by a gradient elution comprising ammonium acetate (10 mM; pH 3.0) and acetonitrile in an 18 min run time at a flow rate of 0.8 ml/min with retention times of 11.8 min (Rh) and 5.9 min (IS). The results revealed that the proposed method is linear over a range of 200–20,000 ng/ml (r 2 > 0.9988) of Rh and is precise and accurate. The method was fully validated as per the US Food and Drug Administration guidelines and a pharma-cokinetic study in rats was performed for Rh following oral administration of the pure DIA and newly developed eutectics. Therefore, the present method could be used to estimate DIA to illustrate a comparative pharmacokinetic analysis. This can also be applied to its related multicomponent formulations for future studies. en_US
dc.language.iso en en_US
dc.publisher Biomedical Chromatography, Wiley Analytical Science en_US
dc.subject diacerein, en_US
dc.subject RP-HPLC en_US
dc.subject rhein en_US
dc.subject pharmacokinetics en_US
dc.subject eutectic en_US
dc.title RP-HPLC method development, validation and pharmacokinetic applicability in preclinical evaluation of rhein treated with novel diacerein eutectics en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account